Drawings & field notes

See how the
pieces relate.

Original evidence, drawn clearly. Enlarge a drawing to inspect it, or download the vector file for a sharp print.

An exploded view of the documented floor stages, with unknown materials and thicknesses kept visible.Enlarge drawing ↗

Photo-based assembly study

The floor, layer by layer

An exploded view of the documented floor stages, with unknown materials and thicknesses kept visible.

Download sharp vector drawing ↓
Read the related chapter
Three photographed stages explain the roof opening, temporary clamping and receiving flange.Enlarge drawing ↗

Photo-based detail drawing

Before the fan covers it

Three photographed stages explain the roof opening, temporary clamping and receiving flange.

Download sharp vector drawing ↓
Read the related chapter
A component overview with identified controller and series-connected 12V, 220Ah bank. See the separate DC wiring redraw for connections.Enlarge drawing ↗

Component overview · not a wiring schematic

The recorded power system

A component overview with identified controller and series-connected 12V, 220Ah bank. See the separate DC wiring redraw for connections.

Download sharp vector drawing ↓
Read the related chapter
A source-faithful redraw of the owner-confirmed October 2020 notebook. Handwritten fuse values and unitless cable callouts are preserved; suitability, cable units and individual load circuits require verification.Enlarge drawing ↗

Notebook wiring redraw · source values

Walter’s finished DC wiring

A source-faithful redraw of the owner-confirmed October 2020 notebook. Handwritten fuse values and unitless cable callouts are preserved; suitability, cable units and individual load circuits require verification.

Download sharp vector drawing ↓
Read the related chapter
Identified AC components and their functions, with concealed terminal routing and grounding left unresolved. This is a functional study, pending an installed-wire trace.Enlarge drawing ↗

AC functional study · trace still needed

Shore, inverter and AC charging

Identified AC components and their functions, with concealed terminal routing and grounding left unresolved. This is a functional study, pending an installed-wire trace.

Download sharp vector drawing ↓
Read the related chapter
Map closed equipment, operating movement and service access before sizing the cabinet.Enlarge drawing ↗

Planning relationship study

The kitchen’s three envelopes

Map closed equipment, operating movement and service access before sizing the cabinet.

Download sharp vector drawing ↓
Read the related chapter
A functional map of the recorded sink and separate rooftop systems. Concealed hose routes and pressure settings remain unverified.Enlarge drawing ↗

Functional system map

Supply, use and wastewater

A functional map of the recorded sink and separate rooftop systems. Concealed hose routes and pressure settings remain unverified.

Download sharp vector drawing ↓
Read the related chapter
An explanatory layer/access study of the recorded mattress, removable slats, frame and drawer bays.Enlarge drawing ↗

Photo-based access study

The bed and the space below

An explanatory layer/access study of the recorded mattress, removable slats, frame and drawer bays.

Download sharp vector drawing ↓
Read the related chapter
The relationship between opening width, side allowances and outside drawer width, with the front treated separately.Enlarge drawing ↗

Geometry worksheet

Make room for the hardware

The relationship between opening width, side allowances and outside drawer width, with the front treated separately.

Download sharp vector drawing ↓
Read the related chapter
Dated views separate localized damping, a foil-faced rigid panel and grooved lining. This is a comparison of visible stages, not a verified final cross-section.Enlarge drawing ↗

Dated photo-stage comparison

Three views of the ceiling build

Dated views separate localized damping, a foil-faced rigid panel and grooved lining. This is a comparison of visible stages, not a verified final cross-section.

Download sharp vector drawing ↓
Read the related chapter
Rails, spacers and opening relationships explain the photographed wall fitting. Dimensions and concealed attachments remain unresolved.Enlarge drawing ↗

Photo-based fitting study

From wall supports to a fitted panel

Rails, spacers and opening relationships explain the photographed wall fitting. Dimensions and concealed attachments remain unresolved.

Download sharp vector drawing ↓
Read the related chapter
Extrusions, plates, bolt heads and panel backs are shown from photographed views. The unresolved roof foot and structural load path are deliberately omitted.Enlarge drawing ↗

Visible-interface study · incomplete mounting design

The visible roof-mount interfaces

Extrusions, plates, bolt heads and panel backs are shown from photographed views. The unresolved roof foot and structural load path are deliberately omitted.

Download sharp vector drawing ↓
Read the related chapter

A drawing’s job is to explain

These illustrations identify their source and verification limits. None is a measured cut plan, load assessment or approved electrical installation design. The original handwritten electrical page remains available in the electrical notebook.

Find your way through the build

100%Download SVG ↓